TWIST PO12-2

Purposes

Power supply organizer TWIST PO12-2 is designed to supply a stabilized 12V voltage cameras and other equipment, as well as the circuits protection of overloaded voltage. It can be used for remote power supply for video cameras in the multi-power circuit security television systems.

Operating conditions

Operating Temperature Range -40 to +55°С
Relative humidity 0 to 100%

Specification

Input voltage, current up to 2 A 15–36 V DC/AC
The number of simultaneously connected loads 1-5
Stabilized output voltage 12 V +/-3%
The output voltage pulses in the range 20MGts up to 30 mV (between peaks)
Total output load current (all channels) up to 2 A
Maximum power consumption 35 W
Protection availability  
    - incorrect input polarity yes
    - overheating yes
    - input overvoltage yes
    - output overcurrent yes
    - output overvoltage yes
Dimensions 142х102х56 mm
Warranty period 36 months

Installation and maintenance

The device comes as the outdoor case IP-66.

  1. Before switching on, connect the input and output cables according to the label on the lid of the device and tight the hermetic input nuts. For the sealing of the case do not leave unused hermetic inputs without cable (you can insert small pieces of the cable and tight the hermetic input nuts).
  2. Make sure that the parameters of the input voltage and total current consumption of pluged loads (cameras) are consistent with those in the specification.
  3. Supply power to the device and determine its status in the table below.
LED is on Mode Output voltage Reason Action
No light
Unknown 0 V 1. The device is not connected

2. Input overload, F1 is out of service
1. Check the connection of input and fuse F1

2. Replace F1
Green
Normal 12 V    
Yellow

or

(Green + Yellow)
Stabilization collapse Below normal values Low input voltage of the connected load Increase the input voltage or reduce the current consumption of the load
Red

+

(Green or Yellow)
Fuse F2 is broken Unknown Output overload Replace fuse F2